LUMETRONICS started an electrical CALIBRATION Laboratory
in 1996 to carry out in-house calibration of test equipment, traceable
to national standards. With the increasing global trend for
standardization and quality assurance, traceable calibration becomes
essential for all test and measuring equipment. The addition of
sophisticated equipment to our laboratory allows us to calibrate
LUMETRON Test Equipment & also other equipment which come under our
calibration ranges.
Some of the equipment in our
laboratory :
Multi
Function
Calibrator
-
Fluke
5500
Source for Voltage, Current, Power, Resistance, Capacitance, Frequency,
Temperature, Power Factor, Harmonics etc |

|
Current
Coil
-
Fluke
550
550 Amps DC/AC
for Clamp Meters
|

|
High
Voltage
Probe
-
Fluke
6kV DC / 4.3kV AC |

|
High
Voltage
Probe
-
Fluke
40 kV DC / 28kV AC
|

|
Precision
Multi
Meter
-
Keithley
KTH
2000
Measure Voltage, Current, Resistance, Frequency, Temperature, etc. |

|
Data
Logging
Multi
Meter
-
Rishab
R16s
Measure Voltage,
Current, Resistance, Frequency, Temperature, etc. |

|
Precision
Analog
Meters
Yokogowa
750 V, 50 A AC, Class 0.2
|

|
Calibrated
Current
Transformer
upto 600 A AC
|

|
Calibrated
Shunt
upto 100 A AC
|

|
Resistance
Decade
Box
1
ohm
to
10kOhm
|

|
High
Voltage
Insulation
Tester
Kyoritsu
|

|
Precision
Weighing
Scale
Ohaus
0.01g to 4000g |

|
Spring
Impact
Hammer
Calibrator
(IEC 60068-2-75)
0.10 Nm to 1.00 Nm |

|
Profile
Projector
with
Quadra Check
up to 300mm
|

|
New Additions and FacilitiesTop
- Revised 'Cal Report' format now includes additional
information.
- 'As Received' and 'As Left' data enable analysis
of instrument stability, drift etc.
- Detailed information about Customer, Instrument,
Environment and Traceability of standards.
- Automated and continuous logging of Laboratory
environmental conditions for Temperature, Humidity and Lighting Levels
using state-of-the-art stand alone logger.
- Annual reminder system. Customers receive a Re-Cal
reminder 11 months after calibration so that instruments can be sent
for calibration in time to maintain their traceability.
DownloadTop
The following catalogs are in 'PDF' format. If you do not have Acrobat
Reader installed on your machine, get it from Adobe website
Calibration Capabilities 
Calibration Ranges 
Parameters such as Voltage (DC, AC), Current (DC, AC), Power (DC, AC -
Single Phase), Resistance, Capacitance, Frequency, Temperature
(indicators), Phase - Power Factor - Harmonics etc. are presently
covered.
Information Request FormTop
|
|
|